Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification

19 March 2026

Prototype Nephelometre aeronautique Arlumen

Focus on a case study: The redesign of a reliable, robust nephelometer adapted to the aeronautical environment.

Aeronautical qualification requires instruments capable of accurately measuring, under flight conditions, the quantity and size of the water droplets and ice crystals responsible for icing. Arlumen acted as a photonics expert partner, responsible for the design, integration and optimization of the optical detection chain.

Technological challenges

The qualification nephelometer is installed on board the aircraft, replacing a window, and incorporates a retractable measuring rod deployed outside the aircraft for test phases.

The system must :

  • Take account of the severe mechanical, thermal and vibratory stresses associated with flight conditions, to guarantee precision and signal quality.
  • Detect particles linked to ice formation ranging from a few microns to 500 microns.
  • Ensure optimum image quality and rigorous optical cleanliness to guarantee faithful particle representation.
3D design of nephelometer on bench

Solution designed by Arlumen

  • Fiberization of a pulsed laser (532 nm) with spectral spreading on three lines via the Raman effect to limit speckle, requiring precise calculation of fiber lengths and two-way separation with a nominal power ratio of 2.7.
  • Integration of optics and their mechanical supports, followed byassembly, mounting and precisionalignment to ensure vibration stability and measurement beam quality.
  • Dual-channel architecture forsimultaneous imaging of different particle sizes:
    • Droplets: magnification ≈ 3 and a field of view of ⌀ = 1.7 mm
    • Frost crystals: magnification ≈ 0.33 and a field of view of ⌀ =7.6 mm
  • Diffraction imaging : optical acquisition coupled with a dedicated image analysis algorithm (out of scope), enabling reliable, quantitative particle detection.

Example of Arlumen aeronautical nephelometer imaging system

Achieved performance

  • Customized photonics system for umbroscopy measurements
  • Multi-scale imaging: resolution from 7 microns to 500 microns
  • Acquisition speed > 170 fps
  • Mechanical and optical vibration stability
  • Fiber laser operational from -15 °C to +55 °C

Images

Arlumen aeronautical nephelometer bench mounting
3D CAD Aeronautical Nephelometer Arlumen
Aeronautical Production Nephelometer Arlumen
Prototype Nephelometre aeronautique Arlumen

Discover also

Spatial & défense
Système de vision

Design of a moon- and star-simulator that accurately replicates real-world space conditions

Autres
Lidar & TOF

Development of a line tracking sensor: Photonics applied to logistics.

Do you have a photonics project?