{"id":1933,"date":"2026-03-19T14:05:54","date_gmt":"2026-03-19T14:05:54","guid":{"rendered":"https:\/\/www.arlumen.fr\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/"},"modified":"2026-03-30T06:48:02","modified_gmt":"2026-03-30T06:48:02","slug":"re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification","status":"publish","type":"realisation","link":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/","title":{"rendered":"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>Focus on a case study: The redesign of a reliable, robust nephelometer adapted to the aeronautical environment.<\/strong><\/h2>\n\n<p class=\"wp-block-paragraph\">Aeronautical qualification requires instruments capable of accurately measuring, under flight conditions, the quantity and size of the water droplets and ice crystals responsible for icing. Arlumen acted as a photonics expert partner, responsible for the design, integration and optimization of the optical detection chain. <\/p>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\"><strong>Technological challenges<\/strong><\/h2>\n\n<p class=\"wp-block-paragraph\">The qualification nephelometer is installed on board the aircraft, replacing a window, and incorporates a retractable measuring rod deployed outside the aircraft for test phases.<\/p>\n\n<p class=\"wp-block-paragraph\">The system must :<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Take account of the severe mechanical, thermal and vibratory stresses associated with flight conditions, to guarantee precision and signal quality.<\/li>\n\n\n\n<li>Detect particles linked to ice formation ranging from a few microns to 500 microns.<\/li>\n\n\n\n<li>Ensure optimum image quality and rigorous optical cleanliness to guarantee faithful particle representation.<\/li>\n<\/ul>\n\n<figure class=\"wp-block-image is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"737\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Design-3d-Nephelometre-band-de-test-aeronautique-Arlumen-1024x737.png\" alt=\"3D design of nephelometer on bench\" class=\"wp-image-1855\" style=\"aspect-ratio:1.389420419135336;width:406px;height:auto\" srcset=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Design-3d-Nephelometre-band-de-test-aeronautique-Arlumen-980x705.png 980w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Design-3d-Nephelometre-band-de-test-aeronautique-Arlumen-480x345.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/figure>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h2 class=\"wp-block-heading\"><strong>Solution designed by Arlumen<\/strong><\/h2>\n\n<ul class=\"wp-block-list\">\n<li>Fiberization of a <strong>pulsed laser (532 nm)<\/strong> with <strong>spectral spreading <\/strong>on three lines via <strong>the Raman effect<\/strong> to limit <strong>speckle<\/strong>, requiring precise calculation of fiber lengths and two-way separation with a <strong>nominal power<\/strong> ratio <strong>of 2.7.<\/strong><\/li>\n<\/ul>\n\n<ul class=\"wp-block-list\">\n<li><strong>Integration of optics<\/strong> and their <strong>mechanical supports<\/strong>, followed by<strong>assembly<\/strong>, <strong>mounting<\/strong> and precision<strong>alignment<\/strong> to ensure vibration stability and measurement beam quality.<\/li>\n<\/ul>\n\n<ul class=\"wp-block-list\">\n<li>Dual-channel architecture for<strong>simultaneous imaging<\/strong> of different particle sizes:\n<ul class=\"wp-block-list\">\n<li>Droplets: magnification \u2248 3 and a field of view of \u2300 = 1.7 mm<\/li>\n\n\n\n<li>Frost crystals: magnification \u2248 0.33 and a field of view of \u2300 =7.6 mm<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<ul class=\"wp-block-list\">\n<li><strong>Diffraction imaging <\/strong>: optical acquisition coupled with a dedicated image analysis algorithm (out of scope), enabling reliable, quantitative particle detection.<\/li>\n<\/ul>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"737\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Exemple-systeme-imagerie-nephelometre-aeronautique-Arlumen-1024x737.png\" alt=\"Example of Arlumen aeronautical nephelometer imaging system\" class=\"wp-image-1856 size-full\" srcset=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Exemple-systeme-imagerie-nephelometre-aeronautique-Arlumen-980x705.png 980w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Exemple-systeme-imagerie-nephelometre-aeronautique-Arlumen-480x345.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<h2 class=\"wp-block-heading\"><strong>Achieved performance<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Customized photonics<\/strong> system for <strong>umbroscopy measurements<\/strong><\/li>\n\n\n\n<li>Multi-scale imaging: resolution from <strong>7 microns to 500 microns<\/strong><\/li>\n\n\n\n<li>Acquisition speed <strong>&gt; 170 fps<\/strong><\/li>\n\n\n\n<li><strong>Mechanical<\/strong> and <strong>optical<\/strong> vibration stability<\/li>\n\n\n\n<li>Fiber laser operational from<strong> -15 \u00b0C<\/strong> to <strong>+55 \u00b0C<\/strong><\/li>\n<\/ul>\n<\/div><\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Images<\/h2>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"404\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Montage-sur-banc-nephelometre-aeronautique-Arlumen-1024x404.png\" alt=\"Arlumen aeronautical nephelometer bench mounting\" class=\"wp-image-1857\" style=\"aspect-ratio:2.534672331561874\" srcset=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Montage-sur-banc-nephelometre-aeronautique-Arlumen-980x386.png 980w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Montage-sur-banc-nephelometre-aeronautique-Arlumen-480x189.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"737\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/CAO-3D-Nephelometre-aeronautique-Arlumen-1024x737.png\" alt=\"3D CAD Aeronautical Nephelometer Arlumen\" class=\"wp-image-1853\" style=\"aspect-ratio:1.389420419135336;width:318px;height:auto\" srcset=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/CAO-3D-Nephelometre-aeronautique-Arlumen-980x705.png 980w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/CAO-3D-Nephelometre-aeronautique-Arlumen-480x345.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"809\" height=\"529\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Nephelometre-Production-Aeronautique-Arlumen.png\" alt=\"Aeronautical Production Nephelometer Arlumen\" class=\"wp-image-1854\" style=\"aspect-ratio:1.5292711429668522;width:318px;height:auto\" srcset=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Nephelometre-Production-Aeronautique-Arlumen.png 809w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Nephelometre-Production-Aeronautique-Arlumen-480x314.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 809px, 100vw\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"1125\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg\" alt=\"Prototype Nephelometre aeronautique Arlumen\" class=\"wp-image-1878\" style=\"aspect-ratio:1.5292711429668522;width:321px;height:auto\" srcset=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg 1500w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen-1280x960.jpg 1280w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen-980x735.jpg 980w, https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen-480x360.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1500px, 100vw\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Focus on a case study: The redesign of a reliable, robust nephelometer adapted to the aeronautical environment. Aeronautical qualification requires instruments capable of accurately measuring, under flight conditions, the quantity and size of the water droplets and ice crystals responsible for icing. Arlumen acted as a photonics expert partner, responsible for the design, integration and [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1934,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"class_list":["post-1933","realisation","type-realisation","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification - Arlumen<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification - Arlumen\" \/>\n<meta property=\"og:description\" content=\"Focus on a case study: The redesign of a reliable, robust nephelometer adapted to the aeronautical environment. Aeronautical qualification requires instruments capable of accurately measuring, under flight conditions, the quantity and size of the water droplets and ice crystals responsible for icing. Arlumen acted as a photonics expert partner, responsible for the design, integration and [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/\" \/>\n<meta property=\"og:site_name\" content=\"Arlumen\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-30T06:48:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"1125\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/\",\"name\":\"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification - Arlumen\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Prototype-Nephelometre-aeronautique-Arlumen.jpg\",\"datePublished\":\"2026-03-19T14:05:54+00:00\",\"dateModified\":\"2026-03-30T06:48:02+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Prototype-Nephelometre-aeronautique-Arlumen.jpg\",\"contentUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Prototype-Nephelometre-aeronautique-Arlumen.jpg\",\"width\":1500,\"height\":1125,\"caption\":\"Prototype Nephelometre aeronautique Arlumen\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/\",\"name\":\"Arlumen\",\"description\":\"Light is our language\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification - Arlumen","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/","og_locale":"en_US","og_type":"article","og_title":"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification - Arlumen","og_description":"Focus on a case study: The redesign of a reliable, robust nephelometer adapted to the aeronautical environment. Aeronautical qualification requires instruments capable of accurately measuring, under flight conditions, the quantity and size of the water droplets and ice crystals responsible for icing. Arlumen acted as a photonics expert partner, responsible for the design, integration and [&hellip;]","og_url":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/","og_site_name":"Arlumen","article_modified_time":"2026-03-30T06:48:02+00:00","og_image":[{"width":1500,"height":1125,"url":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/","url":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/","name":"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification - Arlumen","isPartOf":{"@id":"https:\/\/www.arlumen.fr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/#primaryimage"},"image":{"@id":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/#primaryimage"},"thumbnailUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg","datePublished":"2026-03-19T14:05:54+00:00","dateModified":"2026-03-30T06:48:02+00:00","breadcrumb":{"@id":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/#primaryimage","url":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg","contentUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/03\/Prototype-Nephelometre-aeronautique-Arlumen.jpg","width":1500,"height":1125,"caption":"Prototype Nephelometre aeronautique Arlumen"},{"@type":"BreadcrumbList","@id":"https:\/\/www.arlumen.fr\/en\/realisation\/re-engineering-an-aircraft-nephelometer-photonics-applied-to-aeronautical-qualification\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.arlumen.fr\/en\/"},{"@type":"ListItem","position":2,"name":"Re-engineering an aircraft nephelometer: Photonics applied to aeronautical qualification"}]},{"@type":"WebSite","@id":"https:\/\/www.arlumen.fr\/en\/#website","url":"https:\/\/www.arlumen.fr\/en\/","name":"Arlumen","description":"Light is our language","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.arlumen.fr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/realisation\/1933","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/realisation"}],"about":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/types\/realisation"}],"author":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/users\/3"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/media\/1934"}],"wp:attachment":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/media?parent=1933"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}