{"id":1590,"date":"2025-01-02T10:42:00","date_gmt":"2025-01-02T10:42:00","guid":{"rendered":"https:\/\/www.arlumen.fr\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/"},"modified":"2026-04-09T15:29:54","modified_gmt":"2026-04-09T15:29:54","slug":"reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output","status":"publish","type":"realisation","link":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/","title":{"rendered":"Reduce the energy consumption of emergency lighting and harmonize light output"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The aim of the project was to achieve a perfectly homogeneous light output while keeping the luminaire's power consumption to a minimum. The Arlumen team contributed its expertise to carry out calculations and optical simulations, resulting in a high-performance, durable lighting system that complies with current safety standards. <\/p>\n\n<h2 class=\"wp-block-heading\"><strong>Project objectives: Optimize a lighting system to homogenize flow and make it sustainable<\/strong><\/h2>\n\n<p class=\"wp-block-paragraph\">Our customer produces lighting systems for building and personal safety signage. To make them more sustainable, they wanted to optimize their lighting systems to reduce energy consumption while improving visual rendering. <\/p>\n\n<p class=\"wp-block-paragraph\">The customer called on Arlumen to carry out the<strong>optical study<\/strong> for this deliverable. We carried out a series of <strong>optical calculations and simulations<\/strong> to obtain optimum illumination for the safety indicators produced by our customer. <\/p>\n\n<p class=\"wp-block-paragraph\">The aim of the project was to achieve a perfectly uniform flux across the entire surface of the pictograms, while keeping the luminaire's power consumption to a minimum, in order to comply with the NF Environnement standard. In order to comply with emergency lighting standards, it was also necessary to have a minimum flux at the luminaire outlet (front face with pictograms). <\/p>\n\n<h2 class=\"wp-block-heading\"><strong>Use surface roughness to diffuse light efficiently<\/strong><\/h2>\n\n<p class=\"wp-block-paragraph\">In order to achieve the desired illumination, it was decided to include surface roughness (also known as charmilles) in the lighting system.<\/p>\n\n<p class=\"wp-block-paragraph\">In this project, the roughness acts as an <strong>optical diffuser<\/strong>. In a material that acts as a <strong>light guide<\/strong>, they allow us to select the areas where the light will be extracted and to even out the light in the lighting system. By adjusting their position, number and characteristics, we can <strong>modify the geometry of the light rays<\/strong> to meet the precise needs of the project, and of the customer.  <\/p>\n\n<p class=\"wp-block-paragraph\">Arlumen first studied different types of <strong>bower (roughness)<\/strong> to choose the most suitable.<br\/>We then carried out<strong> optical calculations and simulations<\/strong>, using ZEMAX software, to determine the number of bowers required, their properties and exact locations to ensure <strong>even, even light diffusion.<\/strong><\/p>\n\n<h2 class=\"wp-block-heading\"><strong>Arlumen's knowledge and optical expertise<\/strong><\/h2>\n\n<p class=\"wp-block-paragraph\">Our team's expertise in optical calculations and simulations has enabled us to define very precisely the location of roughness in<strong> the lighting system<\/strong>. This precision work and research has enabled us to deepen our knowledge of the<strong>use and simulation of surface roughness<\/strong> in our optical projects. <\/p>\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"217\" data-id=\"1159\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite.png\" alt=\"Arlumen photo client optical study safety lighting\" class=\"wp-image-1159\"\/><figcaption class=\"wp-element-caption\">Customer-designed emergency lighting system<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"188\" data-id=\"1157\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite2.png\" alt=\"Arlumen photo client optical study lighting security2\" class=\"wp-image-1157\"\/><figcaption class=\"wp-element-caption\">Luminous diffuser plate designed by our customer, based on Arlumen's optical study.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"215\" data-id=\"1158\" src=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite3.png\" alt=\"Arlumen photo client optical study lighting security3\" class=\"wp-image-1158\"\/><figcaption class=\"wp-element-caption\">Focus on the surface roughness of light-diffusing safety systems<\/figcaption><\/figure>\n<\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>Project keywords<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li><em>Light guide<\/em><\/li>\n\n\n\n<li><em>Optical diffuser<\/em><\/li>\n\n\n\n<li><em>Eco-design approach<\/em><\/li>\n\n\n\n<li><em>Reducing energy consumption<\/em><\/li>\n\n\n\n<li><em>Lighting optimization<\/em><\/li>\n\n\n\n<li><em>Battery optimization<\/em><\/li>\n\n\n\n<li><em>Time extension<\/em><\/li>\n\n\n\n<li><em>Optical calculations<\/em><\/li>\n\n\n\n<li><em>Optical study<\/em><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The aim of the project was to achieve a perfectly homogeneous light output while keeping the luminaire&#8217;s power consumption to a minimum. The Arlumen team contributed its expertise to carry out calculations and optical simulations, resulting in a high-performance, durable lighting system that complies with current safety standards. Project objectives: Optimize a lighting system to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1593,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"class_list":["post-1590","realisation","type-realisation","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reduce the energy consumption of emergency lighting and harmonize light output - Arlumen<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reduce the energy consumption of emergency lighting and harmonize light output - Arlumen\" \/>\n<meta property=\"og:description\" content=\"The aim of the project was to achieve a perfectly homogeneous light output while keeping the luminaire&#8217;s power consumption to a minimum. The Arlumen team contributed its expertise to carry out calculations and optical simulations, resulting in a high-performance, durable lighting system that complies with current safety standards. Project objectives: Optimize a lighting system to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/\" \/>\n<meta property=\"og:site_name\" content=\"Arlumen\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-09T15:29:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite.png\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"217\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/\",\"name\":\"Reduce the energy consumption of emergency lighting and harmonize light output - Arlumen\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Arlumen_photo_client_etude_optique_eclairage_securite.png\",\"datePublished\":\"2025-01-02T10:42:00+00:00\",\"dateModified\":\"2026-04-09T15:29:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Arlumen_photo_client_etude_optique_eclairage_securite.png\",\"contentUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Arlumen_photo_client_etude_optique_eclairage_securite.png\",\"width\":300,\"height\":217,\"caption\":\"Arlumen photo client optical study safety lighting\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/realisation\\\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reduce the energy consumption of emergency lighting and harmonize light output\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/\",\"name\":\"Arlumen\",\"description\":\"Light is our language\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reduce the energy consumption of emergency lighting and harmonize light output - Arlumen","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/","og_locale":"en_US","og_type":"article","og_title":"Reduce the energy consumption of emergency lighting and harmonize light output - Arlumen","og_description":"The aim of the project was to achieve a perfectly homogeneous light output while keeping the luminaire&#8217;s power consumption to a minimum. The Arlumen team contributed its expertise to carry out calculations and optical simulations, resulting in a high-performance, durable lighting system that complies with current safety standards. Project objectives: Optimize a lighting system to [&hellip;]","og_url":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/","og_site_name":"Arlumen","article_modified_time":"2026-04-09T15:29:54+00:00","og_image":[{"width":300,"height":217,"url":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/","url":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/","name":"Reduce the energy consumption of emergency lighting and harmonize light output - Arlumen","isPartOf":{"@id":"https:\/\/www.arlumen.fr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/#primaryimage"},"image":{"@id":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/#primaryimage"},"thumbnailUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite.png","datePublished":"2025-01-02T10:42:00+00:00","dateModified":"2026-04-09T15:29:54+00:00","breadcrumb":{"@id":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/#primaryimage","url":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite.png","contentUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Arlumen_photo_client_etude_optique_eclairage_securite.png","width":300,"height":217,"caption":"Arlumen photo client optical study safety lighting"},{"@type":"BreadcrumbList","@id":"https:\/\/www.arlumen.fr\/en\/realisation\/reduce-the-energy-consumption-of-emergency-lighting-and-harmonize-light-output\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.arlumen.fr\/en\/"},{"@type":"ListItem","position":2,"name":"Reduce the energy consumption of emergency lighting and harmonize light output"}]},{"@type":"WebSite","@id":"https:\/\/www.arlumen.fr\/en\/#website","url":"https:\/\/www.arlumen.fr\/en\/","name":"Arlumen","description":"Light is our language","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.arlumen.fr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/realisation\/1590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/realisation"}],"about":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/types\/realisation"}],"author":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/media\/1593"}],"wp:attachment":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/media?parent=1590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}