{"id":1334,"date":"2023-11-27T12:49:20","date_gmt":"2023-11-27T12:49:20","guid":{"rendered":"https:\/\/www.arlumen.fr\/time-of-flight-precise-distance-measurement-using-light\/"},"modified":"2026-03-13T08:23:31","modified_gmt":"2026-03-13T08:23:31","slug":"time-of-flight-precise-distance-measurement-using-light","status":"publish","type":"post","link":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/","title":{"rendered":"Time of Flight: precise distance measurement using light"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><em>In the course of its various optical engineering projects, the Arlumen team has developed, modified and integrated various systems based on Time of Flight (Tof) analysis for its customers. But what is Time of Flight, and why is this technology of interest to so many sectors, from defense to automotive to healthcare? <\/em><\/p>\n\n<h2 class=\"wp-block-heading\">Time of flight: measuring with light<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>Time of Flight technology<\/strong> is a technique for measuring the time of flight, i.e. the propagation time of an object (wave or particle) in a medium, from a transmitter to a detector (simple sensor, camera, etc.). This technology applies to <strong>acoustic waves<\/strong> (sonar), <strong>radio waves<\/strong> (radar), <strong>ion displacements<\/strong> (mass spectrometry) or <strong>optical waves<\/strong> (lidar). The analyses made possible by ToF are numerous.  <\/p>\n\n<p class=\"wp-block-paragraph\">In this way, we can evaluate:<br\/>- the time between the transmitted and received pulse<br\/>- the phase difference<br\/>- interferometry<br\/>- the frequency shift of the return signal (Doppler-Fizeau effect)<br\/>- coherent detection (heterodyne signal).<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Thanks to these measurements, the ToF can be used to determine <strong>distance<\/strong> (telemetry), <strong>produce 2D or 3D representations of an environment<\/strong> (profilometry, topography), <strong>measure the speed of an object<\/strong> (velocimetry) or <strong>evaluate the object's mass<\/strong> (mass spectrometry).<\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">In optics, the wavelength most commonly used in an open environment is in the <strong>near infrared<\/strong> (or NIR, between 780 nm and 3 \u00b5m). In this case, the light emitter and detector are located as close together as possible. <strong>The light then travels back and forth between emitter and detector<\/strong>. The measurement obtained is therefore equivalent to twice the distance to the target.  <\/p>\n\n<h2 class=\"wp-block-heading\">Time of Flight at the heart of Arlumen developments<br\/>Creating intelligent lighting in medical environments<\/h2>\n\n<p class=\"wp-block-paragraph\">For a <strong>company in the medical sector<\/strong>, Arlumen has designed equipment to <strong>maintain a constant level of illumination<\/strong>, despite the variable distance between the emitter and the target. The aim is to provide the same level of illumination in an area (e.g. an operating field), whether the light source is close or far away, so as to guarantee working comfort for practitioners. <\/p>\n\n<p class=\"wp-block-paragraph\">The equipment features the Espros EPC600XX sensor. It <strong>includes an infrared source specifically designed<\/strong> by Arlumen, as well as a <strong>custom-made electronic control board<\/strong>. As the working distance of the equipment is short (between 0.5 and 3 m), the team chose 2 850 nm LEDs, each emitting 40mW.  <\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/flibustiers-dev-newevosens-pf26.wpserveur.site\/wp-content\/uploads\/Telemetre-laser-pour-eclairage-intelligent-courte-portee.jpg\" alt=\"Laser-telemeter-for-smart-lighting-short-range\" class=\"wp-image-4439\" title=\"Laser-telemeter-for-smart-lighting-short-range\"\/><figcaption class=\"wp-element-caption\"><em>Rangefinder for short-range intelligent lighting<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">The challenges faced by the team in carrying out this project were numerous:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Ensuring eye safety for people <\/strong>in the immediate environment<\/li>\n\n\n\n<li><strong>When adapting lighting, take into account disturbances<\/strong> caused by ambient lighting.<\/li>\n\n\n\n<li><strong>Integrate variations caused by operating temperature<\/strong><\/li>\n\n\n\n<li><strong>Adapt to differences in<\/strong> target <strong>texture<\/strong> when measuring the signal.<\/li>\n<\/ol>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Adapting and integrating a ToF module to guarantee the ocular safety of a glare control system<\/h2>\n\n<p class=\"wp-block-paragraph\">For a defense-related customer, the Arlumen team had the opportunity to design a medium-range rangefinder, for a working distance of between 50 m and 30 km. In order to detect the very low levels of return signals (detection dynamics of 45dB) and very short signals (pulse width of 10ns) of the Time of Flight system, Arlumen opted for high-gain detection electronics, based on an avalanche photodiode. <\/p>\n\n<p class=\"wp-block-paragraph\">In addition, to meet the customer's requirement for lightweight, robust and thermally stable equipment, the structure is made of titanium alloy.<br\/>For this project, Arlumen :<\/p>\n\n<ul class=\"wp-block-list\">\n<li>carried out all <strong>optoelectronic simulations<\/strong><\/li>\n\n\n\n<li><strong>designed the measurement card<\/strong><\/li>\n\n\n\n<li><strong>produced a complete prototype<\/strong><\/li>\n\n\n\n<li><strong>developed an alignment bench<\/strong> to ensure that the source and detector are aligned with the mechanical housing, so that the two zones are superimposed at long range.<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Adapting a glare control system to ensure eye safety<\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/flibustiers-dev-newevosens-pf26.wpserveur.site\/wp-content\/uploads\/Modification-Rangefinder-laser-du-commerce.jpg\" alt=\"Modification-Rangefinder-laser-du-commerce\" class=\"wp-image-4438\" title=\"Modification-Rangefinder-laser-du-commerce\"\/><figcaption class=\"wp-element-caption\"><em>Modifying a commercial laser Rangefinder<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">Arlumen's expertise was called upon to <strong>guarantee the ocular safety of a <\/strong> high-power (5 W optical)<strong>laser<\/strong> <strong>illumination system <\/strong>, as part of a safety-related project. To achieve this, the team integrated and modified the Lightware SF30\/C rangefinder. The Time of Flight infrared channel had to be fiberized in order to be multiplexed with the power source.  <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition, <strong>the average power of the ToF has been increased, while ensuring eye safety<\/strong> for the source. For this equipment, the working wavelength is 905 nm, with a peak power of 65 W and an average power of 65 mW. The operating range is from 1 to 100 m.  <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During this study, Arlumen <strong>built a prototype, developed test benches and produced a pre-production run<\/strong>.<\/p>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Design test benches for an automotive 3D LiDAR system<\/h2>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">In the automotive sector, Arlumen has been asked to <strong>develop and produce several functional test benches for LiDAR systems<\/strong>. The aim of these benches is to <strong>reconstruct the 3D environment <\/strong>around a vehicle. <\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">An initial test bench is used to check that <strong>the VCSEL array is working properly<\/strong>, both in terms of total power and homogeneity. The same applies to the SPAD matrix, to check the homogeneity of measurements. <\/p>\n\n<p class=\"wp-block-paragraph\">A second test bench validates the operation of the assembled system, by measuring <strong>the<\/strong> walk <strong>error<\/strong>. It also includes a fibered system simulating different distances and verifying the correct operation of the <strong>ToF measurement<\/strong>. The bench is capable of verifying different opening angles for the system.  <\/p>\n\n<h2 class=\"wp-block-heading\">Time of Flight: guaranteeing personal safety<\/h2>\n\n<p class=\"wp-block-paragraph\">In open spaces, it' <strong>s vital for optical systems to guarantee personal safety<\/strong>, particularly the risk of glare or eye injury, especially if the source uses laser technology. To this end, Arlumen carries out a series of measurements during the optical simulation phase, followed by the prototyping phase, to ensure that exposure levels comply with current standards. Arlumen has also formed <strong>partnerships to guarantee and certify the safety of the systems it designs.<\/strong>  <\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the course of its various optical engineering projects, the Arlumen team has developed, modified and integrated various systems based on Time of Flight (Tof) analysis for its customers. But what is Time of Flight, and why is this technology of interest to so many sectors, from defense to automotive to healthcare? Time of flight: [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1050,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1334","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-non-classe"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Time of Flight: precise distance measurement using light - Arlumen<\/title>\n<meta name=\"description\" content=\"Understand how Time of Flight enables precise distance measurement using light in demanding technical and industrial applications. Learn more.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Time of Flight: precise distance measurement using light - Arlumen\" \/>\n<meta property=\"og:description\" content=\"Understand how Time of Flight enables precise distance measurement using light in demanding technical and industrial applications. Learn more.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/\" \/>\n<meta property=\"og:site_name\" content=\"Arlumen\" \/>\n<meta property=\"article:published_time\" content=\"2023-11-27T12:49:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-13T08:23:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Maquet-Prototype-2_2-scaled-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"hjtykrre\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"hjtykrre\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/\"},\"author\":{\"name\":\"hjtykrre\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#\\\/schema\\\/person\\\/4cc3f9e04941a2dbf26c5e23ccbc6306\"},\"headline\":\"Time of Flight: precise distance measurement using light\",\"datePublished\":\"2023-11-27T12:49:20+00:00\",\"dateModified\":\"2026-03-13T08:23:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/\"},\"wordCount\":917,\"image\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Maquet-Prototype-2_2-scaled-1.jpg\",\"articleSection\":[\"Non class\u00e9\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/\",\"name\":\"Time of Flight: precise distance measurement using light - Arlumen\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Maquet-Prototype-2_2-scaled-1.jpg\",\"datePublished\":\"2023-11-27T12:49:20+00:00\",\"dateModified\":\"2026-03-13T08:23:31+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#\\\/schema\\\/person\\\/4cc3f9e04941a2dbf26c5e23ccbc6306\"},\"description\":\"Understand how Time of Flight enables precise distance measurement using light in demanding technical and industrial applications. Learn more.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Maquet-Prototype-2_2-scaled-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.arlumen.fr\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/Maquet-Prototype-2_2-scaled-1.jpg\",\"width\":2560,\"height\":1920,\"caption\":\"Maquet Prototype 2 2 scaled\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/time-of-flight-precise-distance-measurement-using-light\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Time of Flight: precise distance measurement using light\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/\",\"name\":\"Arlumen\",\"description\":\"Light is our language\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/#\\\/schema\\\/person\\\/4cc3f9e04941a2dbf26c5e23ccbc6306\",\"name\":\"hjtykrre\",\"sameAs\":[\"https:\\\/\\\/www.arlumen.fr\"],\"url\":\"https:\\\/\\\/www.arlumen.fr\\\/en\\\/author\\\/hjtykrre\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Time of Flight: precise distance measurement using light - Arlumen","description":"Understand how Time of Flight enables precise distance measurement using light in demanding technical and industrial applications. Learn more.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/","og_locale":"en_US","og_type":"article","og_title":"Time of Flight: precise distance measurement using light - Arlumen","og_description":"Understand how Time of Flight enables precise distance measurement using light in demanding technical and industrial applications. Learn more.","og_url":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/","og_site_name":"Arlumen","article_published_time":"2023-11-27T12:49:20+00:00","article_modified_time":"2026-03-13T08:23:31+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Maquet-Prototype-2_2-scaled-1.jpg","type":"image\/jpeg"}],"author":"hjtykrre","twitter_card":"summary_large_image","twitter_misc":{"Written by":"hjtykrre","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#article","isPartOf":{"@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/"},"author":{"name":"hjtykrre","@id":"https:\/\/www.arlumen.fr\/en\/#\/schema\/person\/4cc3f9e04941a2dbf26c5e23ccbc6306"},"headline":"Time of Flight: precise distance measurement using light","datePublished":"2023-11-27T12:49:20+00:00","dateModified":"2026-03-13T08:23:31+00:00","mainEntityOfPage":{"@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/"},"wordCount":917,"image":{"@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#primaryimage"},"thumbnailUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Maquet-Prototype-2_2-scaled-1.jpg","articleSection":["Non class\u00e9"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/","url":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/","name":"Time of Flight: precise distance measurement using light - Arlumen","isPartOf":{"@id":"https:\/\/www.arlumen.fr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#primaryimage"},"image":{"@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#primaryimage"},"thumbnailUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Maquet-Prototype-2_2-scaled-1.jpg","datePublished":"2023-11-27T12:49:20+00:00","dateModified":"2026-03-13T08:23:31+00:00","author":{"@id":"https:\/\/www.arlumen.fr\/en\/#\/schema\/person\/4cc3f9e04941a2dbf26c5e23ccbc6306"},"description":"Understand how Time of Flight enables precise distance measurement using light in demanding technical and industrial applications. Learn more.","breadcrumb":{"@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#primaryimage","url":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Maquet-Prototype-2_2-scaled-1.jpg","contentUrl":"https:\/\/www.arlumen.fr\/wp-content\/uploads\/2026\/02\/Maquet-Prototype-2_2-scaled-1.jpg","width":2560,"height":1920,"caption":"Maquet Prototype 2 2 scaled"},{"@type":"BreadcrumbList","@id":"https:\/\/www.arlumen.fr\/en\/time-of-flight-precise-distance-measurement-using-light\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.arlumen.fr\/en\/"},{"@type":"ListItem","position":2,"name":"Time of Flight: precise distance measurement using light"}]},{"@type":"WebSite","@id":"https:\/\/www.arlumen.fr\/en\/#website","url":"https:\/\/www.arlumen.fr\/en\/","name":"Arlumen","description":"Light is our language","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.arlumen.fr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.arlumen.fr\/en\/#\/schema\/person\/4cc3f9e04941a2dbf26c5e23ccbc6306","name":"hjtykrre","sameAs":["https:\/\/www.arlumen.fr"],"url":"https:\/\/www.arlumen.fr\/en\/author\/hjtykrre\/"}]}},"_links":{"self":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/posts\/1334","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/comments?post=1334"}],"version-history":[{"count":3,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/posts\/1334\/revisions"}],"predecessor-version":[{"id":1365,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/posts\/1334\/revisions\/1365"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/media\/1050"}],"wp:attachment":[{"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/media?parent=1334"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/categories?post=1334"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.arlumen.fr\/en\/wp-json\/wp\/v2\/tags?post=1334"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}